NEW Nile Series 502/504/517 models! Designed for non-contact water level measurement. The WaterLOG Nile Series (502/504/517) combines high accuracy with an out-of-the-box measurement range of up to 70 m. The rugged, innovative design was inspired for installation on a bridge or other structure over the water—making this series ideal for sites that may have ice or other instrument-damaging debris. Its reliable interface and simple SDI-12 communication ensure seamless integration with current water monitoring stations. With three models to choose from, the Nile Series is sure to meet your water monitoring needs.
The Nile Series (502/504/517) contains a is reliable interface and simple SDI-12 communication for seamless integration with current water monitoring sites.
Performance | Nile 502 | Nile 504 | Nile 517 |
---|---|---|---|
Standard Accuracy | ±4 mm (0.013 Ft); Target at 1.5 M (5.0 ft) to max range | ±4mm (0.013 Ft); Target at 2.5 M (8.2 ft) to Max range | ±4mm (0.013 Ft); Target at 2.5 M (8.2 ft) to Max range |
Temperature Error Max | ±3 mm (0.01 ft) per 10° C change with ±12 mm (0.039 ft) max error over the complete temperature range of -40°C to +60°C | ±7 mm (0.023 ft) per 10° C change with ±17 mm (0.056 ft) max error over the complete temperature range of -40°C to +60°C | ±7 mm (0.023 ft) per 10° C change with ±17 mm (0.056 ft) max error over the complete temperature range of -40°C to +60°C |
Near Target Error | ±5 mm (0.0164 ft) near target range of 0 to 1.5 M (0 to 5.0 ft) | ±21 mm (0.068 ft) near target range of 0 to 2.5 M (0 to 8.2 ft) | ±21 mm (0.068 ft) near target range of 0 to 2.5 M (0 to 8.2 ft) |
Note |
Errors are additive. Specifications are based on ideal target conditions. |
||
Temperature Error (Limited Temperature Range) | ±2.0mm (0.007 ft) max error per 10° C change | ±5.0mm (0.0164 ft) max error per 10° C change | ±5.0mm (0.0164 ft) max error per 10° C change |
Frequency |
~26 GHz |
~26 GHz |
~26 GHz |
Transmitting Power |
<0.4 nW/cm2 |
<2.5 nW/cm2 |
<2.5 nW/cm2 |
Range |
20m (65.6 ft) |
40m (131.2 ft) |
70m (229.7 ft) |
Measurement |
Nile 502 | Nile 504 | Nile 517 |
---|---|---|---|
Maximum Measurement Error on Low End |
±4.0mm (<1m) 0.16in(<3.28ft) |
±20.0mm (<2m) 0.78in(<6.56ft) |
±20.0mm (<2m) 0.78in(<6.56ft) |
Beam Angle |
10° |
8° |
8° |
Beam Width | Nile 502 | Nile 504 | Nile 517 |
---|---|---|---|
3m (9.84ft) |
.53m (1.74ft) |
.42m (1.38ft) |
.42m (1.38ft) |
6m (19.69ft) |
1.05m (3.45ft) |
.84m (2.76ft) |
.84m (2.76ft) |
9m (29.53ft) |
1.58m (5.18ft) |
1.26m (4.13ft) |
1.26m (4.13ft) |
12m (39.37ft) |
2.10m (6.89ft) |
1.68m (5.51ft) |
1.68m (5.51ft) |
15m (49.22ft) |
2.63m (8.63ft) |
2.10m (6.89ft) |
2.10m (6.89ft) |
20m (65.62ft) |
3.50m (11.48ft) |
2.80m (9.19ft) |
2.80m (9.19ft) |
25m (82.03ft) |
3.50m (11.48ft) |
3.50m (11.48ft) |
|
30m (98.43ft) |
4.20m (13.78ft) |
4.20m (13.78ft) |
|
35m (114.84ft) |
4.89m (16.04ft) |
4.89m (16.04ft) |
|
40m (131.24ft) |
5.59m (18.34ft) |
5.59m (18.34ft) |
|
45m (147.65ft) |
6.29m (20.64ft) |
||
60m (196.86ft) |
8.39m (27.53ft) |
||
70m (229.67ft) |
9.79m (32.12ft) |
Communication | Nile 502 |
---|---|
Output | SDI-12, RS-232 |
Power | |
---|---|
Voltage Input |
10 to 16 VDC |
Supply Current |
Active: 13.5 mA |
Environmental | |
---|---|
Operating Temperature |
-40° C to + 80° C |
Storage Temperature |
-40° C to + 80° C |
Nile KPD - LED Display |
-20° C to +70° C |
Physical | Nile 502 | Nile 504 | Nile 517 |
---|---|---|---|
Size (Housing) |
168mm (6.61in) x 144mm (5.67in) |
||
Size (Horn) |
80mm(3.15in), 115mm (4.53in) x 137.9mm(5.43in) |
100mm(3.94in), 135mm(5.31in) x 150.5mm(5.93in) |
100mm(3.94in), 95mm(3.74 in) x 282mm(11.10 in) |
Weight |
2.7 kg |
2.7 kg |
4.2 kg |
Material (Housing) |
PBT Plastic |
PBT Plastic |
PBT Plastic |
Material (Horn) |
PP Cladded |
PP Cladded |
316L |
Warranty |
The WaterLOG® Nile Series is warranted against defects in materials and workmanship for twenty-four months from date of shipment. For detailed specifications, see user manual. |
||
Note |
*measurements carried out in accordance with EN 61298-3 |