Aanderaa pressure sensors are compact, intelligent pressure sensors designed for use on Aanderaa Data Instruments dataloggers as well as in other measuring systems.
The sensors are based on a silicon piezoresistive bridge sampled and temperature compensated by an advanced Digital Signal Processor. Since all calibration and temperature compensation data is stored internally,pressure can be presented directly in engineering units without any external calculation. The range on both SR10 outputs is user configurable, i.e. confine the range to get optimal resolution.
The sensor is also available in a vented version. This means that the sensor is automatically compensated for air pressure. This is done by use of a compensating unit placed in air and an air-pipe in the cable between the sensor and compensating unit.
Features Pressure Sensor 4017:
• Smart sensor technology - plug and play
• Calibration coeffi cients are stored in the sensor
• Low maintenance needs
• Low current drain
• Depth rating of 6000 meters
• Direct readout of engineering data
• Output parameters: Pressure, Temperature
• Selectable interval from 1 second to 255 minutes
• Rugged and robust with low maintenance needs
• Output formats: SR10, RS-232
• Up to 60MPa range
• Confi gured using Pressure setup program
4047 (or via Hyper Terminal)
Features Pressure Sensor 4117:
• Smart Sensor technology - plug and play
• Calibration coefficients are stored in the sensor
• Low maintenance needs
• Low current drain
• Depth rating of 6000 meters
• Direct readout of engineering data
• Output parameters: Pressure, Temperature
• Selectable interval from 1 second to 255
minutes
• Use with Aanderaa loggers
• Use as stand-alone sensor
• Output formats: AiCaP CANbus, RS-232
• Up to 60MPa range
Features Vented Pressure 4425/4426/4427, Vented Tide 4445/4446/4447, Vented Wave 4428:
• Smart Sensor technology - plug and play
• Sensor calibration coefficients are stored internally
• Low maintenance needs
• Low current drain
• Short update interval: 1 second to 255 minutes
• 2Hz and 4Hz sampling frequency
• 256, 512, 1024 and 2048 samples
• New updated wave parameters every 1 second
• Output parameters: see overleaf
• Output format: AiCaP CANbus, RS-232 or RS-422
• Real-time XML output
Model | Use | Depth Range(s) |
---|---|---|
4017 | available for Recording Current Meters RCM 9, RCM 9 MkII, RCM 9 IW, RCM 9 LW and RCM 11, Recording Doppler Current Profiler RDCP 600 as well as a stand-alone RS-232 sensor for other applications |
0-6000m* |
4117 | designed to be mounted on the SEAGUARD® Platform, with SmartGuard as well as a stand-alone RS-232 sensor for other applications | 0-6000m |
4117R | designed for use with long cables by means of an RS-422 full duplex interface | 0-6000m |
4425/4426/4427 | vented pressure sensor for use with SmartGuard as well as a stand-alone RS-232 sensor for other applications | 0-20m |
4425R/4426R/4427R | vented pressure sensor for use with long cables by means of an RS-422 full duplex interface | 0-20m |
*The range on both SR10 outputs is user configurable, i.e. confine the range to get optimal resolution.